Atlantic Alfea Extensa A.I. R32






Choose the content that is relevant to you:
Description
The Atlantic Alfea Extensa combines environmentally friendly R32 refrigerant with innovative heat exchanger technology resulting in one of Europe's most popular heat pumps.
With an integrated buffer and expansion vessel, the Alfea Extensa split heat pump range offers a flexible and easy installation for integration within Irish homes.
Features
- 5-year warranty
- Suitable for New Build, Social Housing and retrofit
- Highly efficient COP up to 4.74*
- Intuitive control smart weather compensating controls
- Quiet noise level: 35dB(A)
- R32 refrigerant
- Low-carbon: zero ozone depletion and low global warming potential
- Incomparable reliability: patented co-axial heat exchanger
- Space saving: integrated buffer tank and expansion vessel
- Domestic hot water: hot, efficient and fast re-heat times with the Ideal heat pump cylinder range
We're rated excellent on Trustpilot, here's a few of our reviews.
Product Specification
- Product Information
ALFEA EXTENSA A.I. R32
Designation
Unit
Alfea Extensa A.I 5
Alfea Extensa A.I 6
Alfea Extensa A.I 8
Alfea Extensa A.I 10
MCS ref
KIWA 00027/017 HP
KIWA 00027/018 HP
KIWA 00027/019 HP
KIWA 00027/020 HP
Heat Pump Space Heating [35°C]
ErP Rating
A+++
A+++
A+++
A+++
ηₛ
175%
175%
177%
178%
SCOP
4.39
4.38
4.46
4.51
Heat Pump Space Heating [55°C]
ErP Rating
A++
A++
A++
A++
ηₛ
125%
125%
128%
130%
SCOP
2.92
3.15
3.22
3.28
Heating (A7/W35)
Capacity (kW)
4.50
5.50
7.50
9.50
Power Input (kW)
0.95
1.18
1.69
2.11
COP
4.74
4.64
4.43
4.50
Air Temperature Range (°C)
Min/Max
-20/ +35
-20/ +35
-20/ +35
-20/ +35
Sound Data Outdoor Unit / Indoor Unit
Pressure Level 5m Outdoor / 1m Indoor dB(A)*
35/32
35/32
38/32
39/32
Power Level dB(A)**
57/40
57/40
60/40
62/40
MCS 020 (Q2) 4m to assessment point
Visable
Visable
Barrier (partial view)
Barrier (partial view)
42dB(A) | Pass
42dB(A) | Pass
42dB(A) | Pass
42dB(A) | Pass
Primary Flow Rate
Min / Max (l/min)
8.1/16.2
9.9/19.8
13.5/26.9
17.01/34.12
Pipework Connection Sizes
Heating F/R (mm)
28
28
28
28
Gas Pipe - refrigeration (in)
1/2
1/2
1/2
5/8
Liquid Pipe - refrigeration (in)
1/4
1/4
1/4
3/8
Dimensions Outdoor Unit (mm)
Width
866
866
907
940
Depth
324
324
349
365
Height
632
632
716
996
Dimensions Outdoor Unit (mm)
Width
448
448
448
448
Depth
477
477
477
477
Height
847
847
847
847
Weight (kg)
Outdoor Unit / Indoor Unit
39/42
39/42
42/42
60/46
Electrical Data
Electrical Supply (50 Hz)
230 V
230 V
230 V
230 V
Phase
Single
Single
Single
Single
Maximum Running Current [Nominal] (A)
13
13
18
19
Back-up Heater (kW)
3
3
3
3
Fuse Rating - MCB Sizes Type D (A)*****
16
16
25
25
Refrigerant Charge (kg)****
R32
0.97
0.97
1.02
1.63
Documents and resources for Homeowners
Need help with your boiler or control? Download our guides for more technical information on your boiler.
User Guides
Installation & Servicing
Spec Sheets
Description
The Atlantic Alfea Extensa combines environmentally friendly R32 refrigerant with innovative heat exchanger technology resulting in one of Europe's most popular heat pumps.
With an integrated buffer and expansion vessel, the Alfea Extensa split heat pump range offers a flexible and easy installation for integration within Irish homes.
Features
- 5-year warranty
- Suitable for New Build, Social Housing and retrofit
- Highly efficient COP up to 4.74*
- Intuitive control smart weather compensating controls
- Quiet noise level: 35dB(A)
- R32 refrigerant
- Low-carbon: zero ozone depletion and low global warming potential
- Incomparable reliability: patented co-axial heat exchanger
- Space saving: integrated buffer tank and expansion vessel
- Domestic hot water: hot, efficient and fast re-heat times with the Ideal heat pump cylinder range
We're rated excellent on Trustpilot, here's a few of our reviews.
Product Specification
- Product Information
ALFEA EXTENSA A.I. R32
Designation
Unit
Alfea Extensa A.I 5
Alfea Extensa A.I 6
Alfea Extensa A.I 8
Alfea Extensa A.I 10
MCS ref
KIWA 00027/017 HP
KIWA 00027/018 HP
KIWA 00027/019 HP
KIWA 00027/020 HP
Heat Pump Space Heating [35°C]
ErP Rating
A+++
A+++
A+++
A+++
ηₛ
175%
175%
177%
178%
SCOP
4.39
4.38
4.46
4.51
Heat Pump Space Heating [55°C]
ErP Rating
A++
A++
A++
A++
ηₛ
125%
125%
128%
130%
SCOP
2.92
3.15
3.22
3.28
Heating (A7/W35)
Capacity (kW)
4.50
5.50
7.50
9.50
Power Input (kW)
0.95
1.18
1.69
2.11
COP
4.74
4.64
4.43
4.50
Air Temperature Range (°C)
Min/Max
-20/ +35
-20/ +35
-20/ +35
-20/ +35
Sound Data Outdoor Unit / Indoor Unit
Pressure Level 5m Outdoor / 1m Indoor dB(A)*
35/32
35/32
38/32
39/32
Power Level dB(A)**
57/40
57/40
60/40
62/40
MCS 020 (Q2) 4m to assessment point
Visable
Visable
Barrier (partial view)
Barrier (partial view)
42dB(A) | Pass
42dB(A) | Pass
42dB(A) | Pass
42dB(A) | Pass
Primary Flow Rate
Min / Max (l/min)
8.1/16.2
9.9/19.8
13.5/26.9
17.01/34.12
Pipework Connection Sizes
Heating F/R (mm)
28
28
28
28
Gas Pipe - refrigeration (in)
1/2
1/2
1/2
5/8
Liquid Pipe - refrigeration (in)
1/4
1/4
1/4
3/8
Dimensions Outdoor Unit (mm)
Width
866
866
907
940
Depth
324
324
349
365
Height
632
632
716
996
Dimensions Outdoor Unit (mm)
Width
448
448
448
448
Depth
477
477
477
477
Height
847
847
847
847
Weight (kg)
Outdoor Unit / Indoor Unit
39/42
39/42
42/42
60/46
Electrical Data
Electrical Supply (50 Hz)
230 V
230 V
230 V
230 V
Phase
Single
Single
Single
Single
Maximum Running Current [Nominal] (A)
13
13
18
19
Back-up Heater (kW)
3
3
3
3
Fuse Rating - MCB Sizes Type D (A)*****
16
16
25
25
Refrigerant Charge (kg)****
R32
0.97
0.97
1.02
1.63